          Loading...
          高壓差分探頭TMDP0200 - THDP0200 - THDP0100 - P5200A - P5202A - P5205A - P5210A

          高壓差分探頭用于測量兩個均非為地的測試點之間的電壓差。泰克的高壓差分探頭可用于高達 6000 V 的信號。這類探頭由于具有共模抑制能力,成為較大部件中進行非地參考、浮動或隔離測量的良好選擇。這些產品由泰克設計、制造和維修。

          泰克高壓差分探頭解決方案提供:

          優秀的帶寬和探頭負載影響

          符合第三方安全認證的產品(UL、CSA、ETL)

          高壓和中壓產品,支持不同動態范圍和測量分辨率的需要

          全面的探頭附件

          項目服務:輝科實業  技術支持:13063638652



          產品簡介 / Introduction

          產品概述

          Tektronix offers a broad portfolio of high-voltage probing solutions that enable users to safely and accurately make floating measurements.

          Key performance specifications

          • Bandwidths up to 200 MHz

          • Up to 6000 V differential (DC + pk AC)

          • Up to 2300 V common (RMS)

          Key features

          • Overrange Indicator

          • Safety Certified

          • Switchable Attenuation

          • Switchable bandwidth limit

          Applications

          • Floating measurements

          • Switching power supply design

          • Motor drive design

          • Electronic ballast design

          • CRT display design

          • Power converter design and service

          • Power device evaluation

          Connectivity

          • BNC interface (P5200A probes)

          • TekVPI? interface (TMDP and THDP Series probes)

          • TekProbe? interface (P5202A, P5205A, and P5210A Series probes)

          Safe high-voltage probe solutions

          The THDP0100 and P5210A have the largest differential dynamic range capability from Tektronix, allowing users to safely measure up to ±6000 V. The THDP0100 supports bandwidths up to 100 MHz and slew rates up to 2500 V/ns at 1/1000 gain. These probes are supplied with two sizes of hook tips and have an overrange visual and audible indicator which warns the user when they are exceeding the linear range of the probe.

          The THDP0200 and P5205A are active differential probes that are capable of safely measuring differential voltages up to ±1500 V. The probes are effective in making measurements in IGBT circuits such as motor drives and power converters. The THDP0200 supports bandwidths up to 200 MHz and slew rates up to 275 V/ns at 1/250 gain.

          The TMDP0200 and P5202A are designed for medium-voltage applications with differential requirements up to ±750 V. These probes have lower attenuation ranges and offer better signal-to-noise ratio.

          The P5200A can be used with any oscilloscope and enables users to safely make measurements of floating circuits with their oscilloscope grounded. The P5200A Active Differential Probe converts floating signals to low-voltage ground-referenced signals that can be displayed safely and easily on any ground-referenced oscilloscope.

          For safe operation, do not use the P5200A High-voltage Differential Probe with oscilloscopes that have floating inputs (isolated inputs), such as the Tektronix TPS2000 and THS3000 Series oscilloscopes. The P5200A High-voltage Differential Probe requires an oscilloscope or other measurement instrument with grounded inputs.

          Connectivity options

          The TMDP and THDP Series probes are equipped with the TekVPI? interface which allows smart communication between the oscilloscope and probe. Pushing the probe menu button will launch the probe control menu on the oscilloscope display providing access to all relevant probe settings and controls. These probes are designed to operate on TekVPI? oscilloscopes without requiring the TPA-BNC adapter.

          The P52xxA Series probes are equipped with the Tektronix TekProbe? interface which communicates scale information to the oscilloscope. Direct connections can be made to oscilloscopes configured with the TekProbe? interface or to any oscilloscope when used with the 1103 TekProbe? Power Supply.

          Specifications

          All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.

          Model overview

          ProbesTekVPI

          Probes with the TekVPI? interface

          TMDP0200THDP0200THDP0100
          Attenuation25X / 250X50X / 500X100X / 1000X
          Differential Voltage

          250X: ±750 V

          25X: ±75 V

          500X: ±1500 V

          50X: ±150 V

          1000X: ±6000 V

          100X: ±600 V

          Common Mode Voltage±750 V±1500 V±6000 V
          Maximum Input Voltage-to-Earth

          550 V CAT I

          300 V CAT III

          1000 V CAT II

          600 V CAT III

          2300 V CAT I

          1000 V CAT III

          Bandwidth200 MHz200 MHz100 MHz
          Rise Time<1.8 ns<1.8 ns<3.5 ns
          Slew Rate<275 V/ns at 1/250 gain<650 V/ns at 1/500 gain<2500 V/ns at 1/1000 gain
          Input Impedance at the Probe Tip5 M? || <2 pF10 M? || <2 pF40 M? || <2.5 pF
          Typical CMRR

          DC: > -80 dB

          100 kHz: > -60 dB

          3.2 MHz: > -30 dB

          100 MHz: > -26 dB

          DC: > -80 dB

          100 kHz: > -60 dB

          3.2 MHz: > -30 dB

          100 MHz: > -26 dB

          DC: > -80 dB

          100 kHz: > -60 dB

          3.2 MHz: > -30 dB

          100 MHz: > -26 dB

          Cable Length1.5 m1.5 m1.5 m

          ProbesTekProbe

          Probes with the BNC and TekProbe? interface

          P5200AP5202AP5205AP5210A

          Attenuation

          50X / 500X

          20X / 200X

          50X / 500X

          100X / 1000X

          Differential Voltage

          500X: ±1300 V

          50X: ±130 V

          200X: ±640 V

          20X: ±64 V

          500X: ±1300 V

          50X: ±130 V

          1000X: ±5600 V

          100X: ±560 V

          Common Mode Voltage

          ±1300 V

          ±640 V

          ±1300 V

          ±5600 V

          Maximum Input Voltage-to-Earth

          1000 V CAT II

          450 V CAT l

          300 V CAT ll

          1000 V CAT II

          2300 V CAT l

          1000 V CAT III

          Bandwidth

          50 MHz

          100 MHz

          100 MHz

          50 MHz

          Differential Input Impedance

          10 M? || 2 pF

          5 M? || 2 pF

          10 M? || 2 pF

          40 M? || 2.5 pF

          Input Impedance between each Input and Ground

          5 M? || 4 pF

          2.5 M? || 4 pF

          5 M? || 4 pF

          20 M? || 5 pF

          Typical CMRR

          DC: >80 dB

          100 kHz: >60 dB

          3.2 MHz: >30 dB

          50 MHz: >26 dB

          DC: >80 dB

          100 kHz: >60 dB

          3.2 MHz: >40 dB

          50 MHz: >30 dB

          Cable length1.8 m

          THDP0200 probe label

          TMDP P5200 EN US 51W1119514

          1. The differential voltages the maximum measurable range between the (+) and (-) input leads of the probe. Beyond these limits, the output could be clipped.

          2. The maximum common mode voltage and maximum input voltage-to-earth (RMS) are the maximum voltages that each input lead (+/-) can be from ground.

          江蘇輝科電子實業有限公司

          Jiangsu Huike Electronic Industry Co., Ltd

          咨詢熱線  400-698-5028


          在线精品视频无码专区,中文字幕色逼网,人人摸人人叫人人搞,日韩人妻熟妇无码视频
          <span id="zvxvh"></span>

              <i id="zvxvh"><ins id="zvxvh"><thead id="zvxvh"></thead></ins></i>
                <dl id="zvxvh"><delect id="zvxvh"><font id="zvxvh"></font></delect></dl>

                  <ruby id="zvxvh"></ruby>

                  <em id="zvxvh"></em>
                  <strike id="zvxvh"><del id="zvxvh"></del></strike>